May and October are when trouble starts
Cooling kicks on in May here and heat kicks on in November. A heat pump that sat idle, or ran in a different mode, often shows its weak points the first week it has to work hard again.
Takes about a minute. No obligation.
Cooling kicks on in May here and heat kicks on in November. A heat pump that sat idle, or ran in a different mode, often shows its weak points the first week it has to work hard again.
If your heat pump is struggling in April or October, that's the system telling you something before it has to run full time. Getting it looked at before May or November means a smaller fix now instead of a no-heat or no-cool call once the season is on.

NOAA nClimDiv, 1991–2020 normals
A heat pump low on refrigerant forces the compressor to work harder on every cycle.
Keep running it like that and the compressor is what fails next, not the leak.



Half the homes around Monticello were built in 1985 or earlier, half in 1985 or later. Age by itself does not explain a heat pump acting up. About a quarter of the homes in Drew County are mobile homes, where the air handler and ductwork sit in tighter spaces than a site-built house allows. A heat pump tied to that kind of setup can still fail the same way any heat pump does. A weak capacitor, a low charge, a contactor worn from cycling on and off. Nothing about the house causes that. It is still the same handful of parts, and the same one that tends to go first.
Problems tend to show up in the first weeks of the season, when the load hits a part that was already weak.
Find a contractorA heat pump does not get a season off. A furnace rests all summer and an air conditioner rests all winter, but a heat pump runs the compressor in both directions, all year, so the parts inside it never really get a break between jobs. That matters most for whatever is already the weakest link. A capacitor that is starting to go does not get a few months to recover before the next demand hits it. A contactor with pitted contacts keeps arcing every time the system cycles, no matter which mode it is in. Age on its own does not wear these parts out. Run hours do. A heat pump that has been running steady for years on a sound charge and a clean coil is under less strain than a newer one that has been short cycling on a weak capacitor since it was installed.
A heat pump in heating mode should feel warm at the vent, not cool. Air that feels room temperature or barely warm often means the system is stuck between modes or losing refrigerant. This is usually the first thing a homeowner notices, long before anything stops running.
Some frost on the outdoor coil during a defrost cycle is normal. A heavy coat of ice that doesn't clear on its own means the defrost board, the reversing valve, or a sensor isn't doing its job. Left alone, that ice blocks airflow across the coil and the system keeps losing capacity.
A few things are worth checking before anyone comes out. Look at the outdoor unit and clear away leaves, grass clippings or anything stacked against it, since blocked airflow across that coil shows up as weak heating or cooling inside. Check the thermostat batteries if it uses them, and make sure it's set to the mode you want, not just a temperature. Go to the air handler and look at the filter. A filter clogged with dust chokes airflow the same way a blocked outdoor coil does, and it's the one thing in the whole system you can fix yourself in a minute. If there's a disconnect box or breaker near the outdoor unit, confirm it hasn't been bumped off. None of this fixes a bad capacitor or a refrigerant leak, but it rules out the simple stuff first.
A diagnostic visit starts outside, at the unit itself. A tech checks refrigerant pressures, looks at amp draw on the compressor, and tests the capacitor and contactor under load, since those are the parts that fail quietest right up until they don't. Inside, the air handler gets checked too, the filter, the blower, the coil, because weak airflow on either end can look exactly like a refrigerant problem when it isn't one. The thermostat gets tested in both modes, heating and cooling, to see if the reversing valve actually switches when it's told to. Most of this takes measurements, not guesses. A gauge reading or an amp draw either matches what that part should show or it doesn't, and that's usually enough to point at what's actually failing instead of what might be.