Heat pump stuck on emergency heat in Cabot, AR

RepairHeat PumpLonoke County, AR
Step 1 of 2

What ZIP code is the job in?

A heat pump stuck on emergency heat usually means the outdoor unit has stopped running and the system has switched to its backup electric strip heat. Most thermostats have a switch or setting for this, and in Cabot winters, it tends to get used more than it should. The cause is almost always outside: a frozen coil, a dead capacitor, a compressor that won't start, or a tripped breaker on the outdoor unit. The thermostat is only reporting that the outside half of the system isn't answering, so it leans on the backup heat strips inside to keep the house warm. That backup heat works, but it runs on electric resistance, not the heat pump's normal cycle, so it costs more to run and isn't meant to carry the house through a cold snap on its own. If your system has been on emergency heat for more than a day, the outdoor unit needs a look before the strips end up carrying your whole heating load.

A gray outdoor heat pump unit on a concrete pad beside a house with horizontal lap siding, with a conduit running to a wall-mounted disconnect box and a green shrub to the left.

Normal operation

The outdoor unit runs, pulling heat from the outside air even when it's cold, and the house stays warm without the backup strip heat kicking in. The disconnect box and conduit sit clean and intact, and the unit cycles on and off on its own through the day.

An outdoor air conditioning condenser unit with dusty coils sits on a concrete pad against light horizontal siding, with an electrical disconnect box and refrigerant lines on the wall and a shrub and mulch at left.

Stuck on emergency heat

The outdoor unit sits idle no matter how cold it gets outside, and the furnace or air handler leans on electric strip heat to keep up. A unit this worn, with soil built up around the base and lines running bare into the wall, is one a technician needs to look at.

Why is your electric bill suddenly so much higher

Emergency heat runs on electric strips alone, with no help from the outdoor unit, and strip heat costs more to run than a working heat pump. You'll likely notice it first on the power bill. You might also notice the air coming out of the vents feels hotter than usual, since strip heat warms the house differently than the heat pump does on its own. The outdoor unit will sit still even when you'd expect it to be running, no fan turning, no hum from the compressor. If this goes unfixed through a Cabot winter, the house still stays warm, but you're paying for heat you don't need to be paying for, month after month.

A gray outdoor condenser unit on a concrete pad beside a house with horizontal lap siding, with a wall-mounted disconnect box, conduit and insulated refrigerant lines, a shrub at left and gravel at right.

The outdoor unit is doing its job

The condenser sits on its pad, lines and conduit running up to the disconnect box, and it's actually running. It cycles on its own, pulling heat from the outside air, and nothing is forcing the house onto backup strip heat.

An outdoor air conditioning condenser unit on a concrete pad beside a house with horizontal lap siding, with a green shrub to the left and a wide concrete slab in the foreground.

The outdoor unit has shut down

The condenser sits on the pad but the fan isn't turning and the coil may be iced over or silent when it should be running. When this unit stops, the system falls back to emergency heat and the electric strips carry the whole load.

A woman with long wavy brown hair in a grey ribbed sweater sits on a couch indoors, looking toward a window, with a potted palm-like plant and fireplace behind her.
A woman with long brown hair wearing a green V-neck top and beige cardigan sits on a light sofa, looking off to the side, with a dining table, lamp and framed picture in the background.
A woman with long dark hair in a cream knit sweater sits on a beige sofa indoors, looking toward a bright window with a houseplant and framed picture in the background.
A woman with long dark hair in a green knit sweater sits on a couch indoors, smiling and looking toward a window with a blurred room behind her.

A local pro for your heat pump repair

Get the heat pump repair search off your mind today.

Sending the form costs nothing.

Why the system switches over

  • A thermostat with an emergency heat switch controls it directly, so check that setting before anything else.
  • Some heat pumps switch to emergency heat on their own through a lockout relay when the outdoor unit faults.
  • A tripped breaker, a blown fuse, or a frozen outdoor coil can all force the system into this mode without warning.
  • The outdoor unit's disconnect box has a pull handle, and if it's left open the compressor can't run at all.
  • A defrost control board failure can also tell the system the outdoor unit isn't working, even when it is.
  • Once a contractor clears the fault, the thermostat has to be switched back to normal heat or it stays locked into the strips.

A heat pump has two ways to heat the house, and emergency heat is the backup path. It runs off electric strips in the air handler, not the outdoor unit, so when you see it active, something has told the system the outdoor unit isn't available. Sometimes that's you, through a switch on the thermostat. Sometimes the system decides on its own. A lockout relay watches the outdoor unit, and if it senses a fault there, it locks the compressor out and hands heating over to the strips without asking anyone. That fault can be simple. A breaker tripped. A fuse blew. The outdoor coil iced over and stopped transferring heat the way it should. It can also be the disconnect box next to the outdoor unit. That box has a pull handle, and if it's been left open, even partway, the compressor has no power and can't run no matter what the thermostat calls for. A failed defrost control board causes the same result from the inside. It can report a fault that isn't really there, and the system acts on that bad information just as it would on a real one. Whatever the cause, clearing it is only half the job. The thermostat still has to be switched back from emergency heat to normal heat, or the house keeps running on strips even after the outdoor unit is fixed and ready to work again.

Winter nights average 34°F

At 34°F, your heat pump should still be pulling heat from the outside air just fine. That's not cold enough to need the backup strips running all night. If it's stuck on emergency heat on a night like that, something has shut the outdoor unit down, not the weather.

NOAA nClimDiv 1991-2020

  1. Thermostat calls for heat and checks the outdoor temperature

  2. Outdoor unit should start and pull heat from the air

  3. A fault or lockout stops the outdoor unit from running

  4. The system switches over to electric strip heat alone

A smiling older woman with gray shoulder-length hair in a cream cable-knit turtleneck sweater stands behind a wooden board holding a round loaf of bread, in a warmly lit kitchen with a dark window and shelves behind her.
A woman with dark hair in a bun sits on a sofa with a child resting his head on her shoulder, both wrapped in a cream knit blanket, with a lit lamp and bookshelf in the dim background.

25°F

Most heat pumps around Cabot can still draw heat from outside air down to this point. Emergency heat running above it points to a stuck unit, not the cold.

Get a local pro

No second stage

Emergency heat skips the outdoor unit entirely and runs the electric strips by themselves, which is why the house still warms up while the bill climbs.

Get a local pro
A woman stands in the open front doorway of a single-story house with stone and wood siding while a man in a dark polo shirt and cap walks toward it along a concrete path.

The outdoor unit should be the one doing the work

A heat pump stuck on emergency heat is telling you something specific: the outdoor unit isn't running, and the house is being kept warm by electric strips alone. That's true whether a breaker tripped, a fault locked the system out, or someone bumped the thermostat switch. The fix is different in each case, but the starting point is the same. The outdoor unit needs to come back on.

Once you've checked the thermostat setting and the breaker, the rest is a job for someone who can see what tripped the lockout and get the outdoor unit running again. A contractor who works on heat pumps around Cabot can look at your system, find what shut it down, and let you know what it'll take to get it back to pulling heat the way it's supposed to.

A gray upholstered sofa with a beige cushion and knit blanket beside a curtained window, with a white mug and a book on a dark wooden table in the foreground and a lit lamp in the background.
A gray outdoor air conditioner condenser unit on a concrete pad beside a house with horizontal lap siding, with an electrical disconnect box and conduit on the wall, a downspout, gravel edging and a green lawn with trees to the right.