Night view of illuminated white Southern-style houses with wraparound porches beneath Spanish moss-draped oak trees.

Heat Pump Installation in Stuttgart, AR

Tell us about the job

Takes about a minute. No obligation.

New system or replacementHeat PumpArkansas County, AR
Step 1 of 2

What ZIP code is the job in?

Electric is the default here

Electricity heats 58.2% of homes in Arkansas County, more than gas and propane combined. A heat pump fits that setup without any new fuel line or venting to plan for.

Gas homes still have a path

Utility gas heats 32.9% of homes here, with propane making up another 7.8%. In those homes a heat pump can still go in, but the contractor will need to look at how it works alongside the existing furnace or ductwork.

5 months
November through March, your system heats
5 months
May through September, it cools
36°F
the average winter night it heats against
90°F
the average summer afternoon it cools against
Isometric grayscale illustration of a cutaway two-story house showing interior ductwork, an indoor air handler unit, and an outdoor condenser unit on a pad beside the building.
Your system heats November through March and cools May through September.

NOAA nClimDiv, 1991–2020 normals

Heat here runs November through March, so October is when a heat pump needs to be ready.

Scheduling the install before October means the contractor sets the changeover on a day that works for you, not on the first cold morning.

A standard heat pump sized right fits these homes, no upsizing needed

Half the homes here were built by 1978
Power costs 12.32 cents a kWh statewide
Climate zone 3A

Your new heat pump has to clear a higher bar here

Stuttgart sits in climate zone 3A, and any heat pump installed here has to hit 14.3 SEER2 and 7.5 HSPF2 at minimum. That's the regional floor, not a national one, and it narrows down which systems a contractor will even put on the quote. A federal tax credit is available for qualifying equipment, worth checking into before you settle on a model.

Find a contractor
A gray air-source heat pump mounted on a concrete pad next to a house with gray vinyl siding, surrounded by gravel and flanked by green shrubs and white hydrangea flowers.

The number on the label is a ceiling, not a guarantee

The rating on the label tells you what the system does with the power it draws, not how big a space it can handle. A high rating and the wrong size for your ductwork still gets you a system that runs too long or cycles too much. What that rating does tell you is how hard the compressor works to move heat. A higher rated system moves the same heat using less electricity, year after year, as long as the coils stay clean and the airflow across them stays right. Let the filter clog or the outdoor coil fill with debris and the system has to work harder than its rating promises, no matter what number is on the sticker. The rating is a ceiling, and only steady maintenance keeps the system anywhere near it.

The old furnace or AC comes out

A contractor disconnects the old equipment from the ductwork and the power or gas line, then hauls it away. If a gas furnace is coming out for good, the gas line gets capped off properly, not just shut at the valve. The old condenser gets disconnected and its refrigerant recovered rather than vented, which the law requires anyway.

What stays depends on what's underneath

If the ductwork is already in place and in good shape, the heat pump ties into it and nothing about the duct run changes. An old furnace sometimes stays put as backup heat for the coldest stretches, paired with the new heat pump instead of replaced outright. A contractor can tell you which parts of the old system are worth keeping once they've looked at what's actually there.

When you're comparing quotes, ask what size unit each contractor is proposing, and ask how they arrived at that number. A heat pump sized by square footage alone is a guess. One sized from a load calculation, done room by room, is not. Ask what happens at the lowest outdoor temperatures this system will see, and whether it needs backup heat strips or a paired furnace to get through those stretches, because not every heat pump handles cold the same way. Ask about the sound rating of the outdoor unit too, since some run noticeably quieter than others, and that matters if it sits near a window or a patio. Ask what the warranty covers on the compressor versus the rest of the parts, and whether it requires the contractor who installed it to also do the warranty work. The answers tell you more about the quote than the price does.

Installation day starts outside, with the old condenser pulled and the new one set on its pad and leveled. Refrigerant lines get run and connected, then pressure tested before any charge goes in, because a leak found after charging means recovering the charge and starting over. Once the lines hold, the electrical hookup goes in and the system gets powered on for the first time, with a technician watching the pressures and the temperature across the coil to confirm the charge is right. The thermostat gets set up last, often a new one, since a heat pump controls differently than a furnace and AC did. Before the contractor leaves, airflow gets checked at the vents in every room, not just at the unit, because a system that measures right at the coil can still leave a room short if a duct run is restricted.