Single-story brick and white-sided buildings with covered porches behind a trimmed hedge and lawn, framed by overhanging oak branches draped with Spanish moss.

Heat Pump Repair in Conway, AR

Tell us about the job

Takes about a minute. No obligation.

RepairHeat PumpFaulkner County, AR
Step 1 of 2

What ZIP code is the job in?

Before you call, check the thermostat first. Make sure it's set to heat and the temperature is actually above room temperature, since a setting bumped by accident looks exactly like a broken system. Next, go to the breaker box and look for a tripped breaker on the heat pump circuit. Outside, take a look at the outdoor unit. If it's covered in ice or buried under leaves and debris, airflow is blocked and the system can't work right. Last, check your air filter. A filter clogged with dust chokes off airflow and can cause the whole system to shut down or run constantly without warming the house.

6 months
November through April, your system heats
5 months
May through September, it cools
32°F
the average winter night it heats against
91°F
the average summer afternoon it cools against
Isometric illustration of a cutaway single-story house showing interior ductwork, an indoor air handler and simple furniture, connected by lines to an outdoor condenser unit beside the building.
Your system heats November through April and cools May through September.

NOAA nClimDiv, 1991–2020 normals

An old compressor costs more to replace on its own than to pair with a new system.

If your heat pump is old enough that the compressor failed, the rest of the system is close behind it.

Half the homes in Faulkner County were built in 1998 or later, maybe yours

Half the homes here were built by 1998
90 damaging wind events from 2015 to 2024
64 hail events from 2015 to 2024

A heat pump in Faulkner County switches over to heat in November, and that first cold snap is when a weak system shows itself. The parts that carried the load fine in September get asked to do something different, and if the reversing valve or the defrost control was already marginal, this is when it quits. October is the month to get a repair looked at before that switch happens, not after the house is already cold. Calling in November means waiting behind everyone else whose system picked that same week to fail.

Repair it

If your system came with a newer house, it likely has plenty of life left. Repair is usually the right call.

Find a contractor
A man in a navy shirt and tan trousers, seen from behind, carries a canvas tool bag up wooden porch steps toward a dark blue front door, with shrubs and a large planter nearby.
A residential heat pump outdoor unit mounted on a concrete pad next to a house with gray vinyl siding.

Running it while it's failing is what turns a repair into a replacement

A heat pump that's struggling doesn't fail all at once. It fails a little more every hour it keeps running. A weak capacitor makes the compressor draw harder to start each cycle, and that extra strain wears the windings down faster than if the system got shut off and looked at. A low refrigerant charge makes the compressor run hotter than it should, and heat is what kills a compressor. Ice on the outdoor coil blocks airflow, so the system runs longer to do the same job, and that longer runtime is exactly what melts more wear onto parts already struggling. None of this fixes itself by waiting. The system doesn't rest between cycles, it just starts the next one already behind.

The reversing valve sticks partway

The reversing valve switches a heat pump between heat and cooling. When it sticks, the system runs but blows cool air when it should be warm, or it answers a call for heat with cool air instead. Once it sticks, it doesn't free itself on its own.

A weak capacitor shows up as a hard start

The capacitor gives the compressor and fan motor the jolt they need to start spinning. A weak one makes the compressor hum and struggle before it catches, or it never catches at all. Every hard start like that strains the windings a little more, and a capacitor left bad long enough tends to take the compressor with it.

Most heat pump trouble shows up as a change the homeowner can hear or feel, not something you have to go looking for. Warm air stops coming from the vents, or the air coming out is barely warm at all. The outside unit runs but never seems to satisfy the thermostat, cycling on and off more than it used to. Sometimes the system runs constantly and still can't catch up to the set temperature. A hissing or bubbling sound from the lines points to refrigerant escaping somewhere it shouldn't. Ice building up on the outdoor coil that doesn't clear during the defrost cycle means that part of the system isn't doing its job. Any of these is worth a call, not a wait and see.

A diagnostic call usually starts outside at the unit. The tech checks the coil for ice, looks at the fan blade and motor, and checks the refrigerant lines for oil residue that points to a leak. Gauges go on next to read the refrigerant charge, since too little or too much both cause trouble in different ways. Inside, the tech checks the air handler, the filter, and the blower motor, then runs the system through a full cycle. Forcing it into defrost and back to heat shows whether the reversing valve actually switches when it's told to. Electrical readings come last, the capacitor's output, the contactor's condition, the amp draw on the compressor as it starts and runs. A compressor that draws too much on startup is already telling you something about its windings. The goal is to find which part is causing the symptom, not just confirm that something's wrong. A tech who can show you the failed capacitor or the low charge reading is giving you something to decide from, not just an opinion.