What winter here actually asks of a heat pump
Winter in Faulkner County is mild more than it's cold. The overnight low averages 32°F across December, January and February, and it only reaches that mark or below on about 70 nights a year, under half the nights in the six months the heat runs. Nights at 0°F are rare here, fewer than one a year. That matters because a standard heat pump has two weak points, and this county's winter sits right on top of both. Its heat output falls short of its rating once it's below 40°F outside, and it often needs backup heat once it's below about 35°F. The average winter low here is below both marks, and every one of those 70 freezing nights is too.
That doesn't mean the heat pump stops working. It means on a good share of winter nights, it's running under its rated output and may be leaning on backup heat to make up the difference. A furnace doesn't have this problem. It burns gas and makes its full rated heat whether it's 40°F out or colder.
There's a version of a heat pump built for this. A unit carrying the ENERGY STAR Cold Climate designation has to prove it still makes 1.75 units of heat for every unit of electricity at 5°F, and holds onto at least 70 percent of its warm-weather capacity at that temperature. A two-winter field test of prototype cold-climate units backed this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. Faulkner County barely sees 0°F weather, so a cold-climate heat pump here would be working well inside its range, not at the edge of it. A standard, federal-minimum heat pump is a different bet. On most of the nights that matter here, it's working at the edge of what it's rated for.