What winter here actually asks of a heat pump
Your winter is mild more than it's cold. The average overnight low across December, January and February is 31°F, and freezing nights only add up to about 75 a year, under half the nights in the seven months the heat runs. Nights near 0°F are almost nonexistent here, fewer than one a year. That matters because a heat pump's weak point is deep cold, and this county rarely sees it.
It still matters that 31°F sits below the marks where a standard heat pump struggles. Its heat output falls short of the rating once it's below 40°F outside, and below about 35°F it often leans on backup heat. Every one of those 75 freezing nights falls below both marks. So on an average winter night here, a standard heat pump is working harder than its rating suggests, and may be calling on backup heat to make up the difference.
That's a real limit, but it's not the same as the deep-freeze failure people picture. A two-winter field test of cold-climate heat pumps in occupied homes found backup heat covered only a small share of the heat needed between 0°F and 35°F, and the units ran on backup alone only rarely, even above 0°F. If you want more certainty on the coldest nights, look for the ENERGY STAR Cold Climate mark. To earn it, a heat pump has to keep making real heat, at least 1.75 units out for every unit of electricity in, even at 5°F, and hold onto 70 percent of its warm-weather capacity at that temperature, verified by outside testing rather than the manufacturer's word.