Can a heat pump keep up on a 33 degree night
Winter here is not harsh. The overnight low averages 33°F across December, January and February, and it falls to freezing or below on about 65 nights out of the roughly 150 the heat runs. Fewer than one night a year sees 0°F. That matters because a standard heat pump has two separate limits, and both sit right where this county's winter lives. Below 40°F outside, it puts out less heat than its rating says. Below about 35°F, it often needs backup heat to make up the difference. The average winter low here is under both marks, and every one of those 65 freezing nights is too.
That does not mean a heat pump will leave you cold. It means that on a typical winter night here, a standard heat pump is working below its best range and may be leaning on backup heat to hold the temperature. A heat pump built to the ENERGY STAR Cold Climate spec is tested to a harder number: at 5°F it still has to deliver 1.75 units of heat for every unit of electricity and hold onto 70 percent of its 47°F capacity. A county that rarely sees 0°F, let alone 5°F, is comfortably inside what that spec is built for. Field testing of cold-climate heat pumps in occupied homes backs this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. For Hot Spring County, where the worst nights only touch the edge of that range, a cold-climate heat pump should carry the house on its own almost all winter.